ESTIMATION OF THE THERMOHYDRAULIC EFFICIENCY OF SWIRLERS AT SMALL REYNOLDS NUMBERS
A. F. Ryzhkov,a L. Zhargalkhuu,b Nadir Saman M. Sharif,a and A. D. Makhaeva UDC 621.036.536.244 To estimate the thermohydraulic efficiency of different types of swirlers of heat exchange in pipes, we have generalized the experimental data, which has made it possible to determine the optimal range of Reynolds numbers and the optimal geometric sizes of swirlers. Keywords: transient regime, intensification of heat exchange, twisted tape, wire insert, screw, one-propeller insert, two-propeller insert, thermal efficiency, hydraulic efficiency, energy efficiency. aGOU VPO "Urals State Technical University - UPI," 19 Mir Str., Ekaterinburg, 620002, Russia; email: mahaev-anton@rambler.ru; bMongolian State University of Science and Technology, Ulan-Bator, Mongolia. Translated from Inzhenerno-Fizicheskii Zhurnal, Vol. 82, No. 1, pp. 23-30, January-February, 2009. Original article submitted September 13, 2006; revision submitted May 28, 2008.