POWER EXPENDED FOR PUMPING HEAT-TRANSFER AGENTS AND EFFICIENCY OF THE HEAT EXCHANGE IN CONICAL RADIATIVE SLOT RECUPERATORS
V. E. Loginov UDC 621.184.52:51-7 Formulas for calculating the amount of power expended for the pumping of heat-transfer agents (air and smoke gases) in conical radiative slot recuperators with account for the initial acceleration of these agents, the acceleration of them in the process of their movement, and their friction on the walls of a channel have been derived. The dependence of the energy coefficient on the flow rate of a heated air, pumped in such a recuperator in the forward-flow and counterflow regimes, and on the recuperator length has been determined on the basis of heat-engineering calculations performed with the use of mathematical models involving the formulas derived. Rostov-on-Don State Academy of Agricultural Machinery Industry, 2 Strana Sovetov Sq., Rostov-on-Don, 344023, Russia; email: ve_loginov@mail.ru. Translated from Inzhenerno-Fizicheskii Zhurnal, Vol. 79, No. 2, pp. 174-177, March-April, 2006. Original article submitted July 26, 2004; revision submitted June 27, 2005.