HEAT TRANSFER IN A PLANE THREE-LAYER SYSTEM WITH A HEAT-CONDUCTING NOT-THROUGH ENCLOSURE
A. N. Khutornoi, N. A. Tsvetkov, and S. I. Skachkov UDC 699.86.022.3+666.198:691.87 Consideration is given to the laws of formation of temperature fields in the structure of the outer three-layer brick wall with the use of efficient warmth-keeping jackets and connectors (flexible couplings). The influence of the connector on the temperature field of the wall has been shown. It has been established that most of the heat arrives at the connector through lateral surfaces before the cross section with a maximum value of the transmission heat beyond the region of possible condensation of a water vapor. After this cross section, the heat is removed from the connector to the materials of the outer wall. Satisfactory agreement between the calculated and experimental results has been obtained. State Institution "Scientific-Research Institute of Building Materials" at Tomsk State University of Architecture and Civil Engineering, Tomsk, Russia. Translated from Inzhenerno-Fizicheskii Zhurnal, Vol. 75, No. 5, pp. 146-148, September-October, 2002. Original article submitted December 11, 2001; revision submitted February 22, 2002. JEPTER7492020023 JEPTER749203