HIGH-TEMPERATURE-HEAD HYDROAERODYNAMIC HEAT EXCHANGER
O. I. Rakitin UDC 530.162;536.24 A model of heat exchange and principles of calculation of a hydroaerodynamic heat exchanger (HAHE) on the basis of the theory of locally nonequilibrium processes are presented. The optimum parameters of an HAHE and the principles of its design, which are also true for other mixed locally nonequilibrium systems, have been determined. Institute of Technical Thermal Physics, National Academy of Sciences of Ukraine, Kiev, Ukraine. Translated from Inzhenerno-Fizicheskii Zhurnal, Vol. 75, No. 3, pp. 156-160, May-June, 2002. Original article submitted January 18, 2001; revision submitted October 9, 2001. JEPTER74920200219 JEPTER7492019