COMPLEX MODEL OF THE EFFICIENCY OF RECTIFICATION PLATES.
8. COMPARISON WITH OTHER MODELS WITH RESPECT TO EXPERIMENTAL DATA
V. V. Pavlechko and E. I. Levdanskii
UDC 66.048.375
A complex model is compared with the Murphree and Hausen
models for the cases of concurrent and cross motion of vapor and liquid
phases. Use is made of results of experimental studies involving separation
of an acetic acid-water mixture and industrial data on rectification
of furfurol and ethanol. It is proved that the efficiencies in the
complex and Murphree models coincide as the coefficient of phase equilibrium
m approaches unity but when this coefficient increases, the
first model and the Hausen model coincide. The possibility of using
the Murphree model at m
1 and the Hausen model at m
is shown.
Belarusian State Technological University, Minsk, Belarus.
Translated from Inzhenerno-Fizicheskii Zhurnal, Vol. 75, No. 3,
pp. 17-21, May-June, 2002. Original article submitted June 20, 2001.
JEPTER74920200211
JEPTER7492011