THERMAL CALCULATION OF THE FURNACE CHAMBER OF A FIRE-TUBE BOILER WITH A DEAD-END FURNACE
M. L. German , V. A. Borodulya , and E. F. Nogotov UDC 66.096.5:662.61 An engineering procedure for calculating the thermal regime of the furnace chambers of fire-tube boilers with a dead-end furnace is given. The procedure proposed is devoid of many drawbacks that are inherent in the standard method for calculating boiler units and permits more accurate allowance for the special features of combined energy exchange in furnace chambers of boilers that differ significantly in type and size from traditional ones. JEPTER74920200014 JEPTER7492014