Volume 90,   №3

STRENGTH AND STIFFNESS ANALYSIS BY THE FINITE-DIFFERENCE METHOD OF A CONCRETE FLOOR SLAB REINFORCED WITH COMPOSITE RODS DURING A FIRE



A strength and stiffness comparative analysis has been made of a concrete slab reinforced with compositereinforcement rods and a slab reinforced with steel rods. The stress-strain state has been assessed for both versions of reinforcement of the slab. The stress-strain state was determined under the action of only static load and with subsequent application of temperature fields, i.e., under standard-fi re conditions. It has been shown that the fire resistance of the slab with a composite reinforcement turns out to be 1.6 higher as far as the bearing capacity is concerned, than the fire resistance of the slab with a steel reinforcement, although the initial defl ection due to the action of only static load for the slab reinforced with composite rods exceeds six to seven times the deflеction of the slab reinforced with steel rods.
 
 
Author:  A. V. Shirko, A. N. Kamlyuk, A. S. Drobysh, and A. V. Spiglazov
Keywords:  strength, loading, fi nite-element method, concrete, composite and steel reinforcements, temperature fi elds, stress, fi re resistance
Page:  705

A. V. Shirko, A. N. Kamlyuk, A. S. Drobysh, and A. V. Spiglazov.  STRENGTH AND STIFFNESS ANALYSIS BY THE FINITE-DIFFERENCE METHOD OF A CONCRETE FLOOR SLAB REINFORCED WITH COMPOSITE RODS DURING A FIRE //Journal of engineering physics and thermophysics. . Volume 90, №3. P. 705.


Back to list